• 415 ILCS 5/21.8
  • Sales end Jan 1, 2027
  • T5 · T8 · T10 · T12
  • Pin-base CFL
  • Type A · B · C

From January 1, 2027, no new T5, T8, T10, T12 or pin-base CFL lamp can be sold in Illinois. The fixtures can stay up. When the spare tubes run out, each one gets a tube swap or a new fixture, and the two leave very different rooms.

Jan 1, 2027new linear and pin-base CFL sales end
0.5–8 ftevery tube length, T5 through T12
No sell-offwindow in the Illinois text
Jan 1, 2026screw-base CFLs already off the shelf

01What stops, what stays

Fluorescent lamp sales bans by date: Vermont 4 ft linear lamps 2024; Illinois screw-base CFLs 2026, linear and pin-base CFLs 2027, no-LED-alternative exemption ends 2028; Washington CFL and linear lamps 2029Fluorescent lamp sales bans by date: Vermont 4 ft linear lamps 2024; Illinois screw-base CFLs 2026, linear and pin-base CFLs 2027, no-LED-alternative exemption ends 2028; Washington CFL and linear lamps 2029
Lamp Covers No new sales from
Screw-base CFL Spirals and other screw-in CFLs Jan 1, 2026
Pin-base CFL 2-pin and 4-pin: PL, twin tube, 2D, U-bend, circular Jan 1, 2027
Linear fluorescent T5, T8, T10, T12; 0.5 to 8 ft; straight, U-bend, circular Jan 1, 2027

Source: 415 ILCS 5/21.8 (Public Act 103-0799).

It bans selling lamps. Nothing comes off the ceiling by law, and ballasts and fixtures aren’t in it. The real deadline is the spare shelf: count the tubes on hand by type.

02A tube swap keeps the old ceiling

Mixed lampsTwo lay-in fluorescent troffers on a dark ceiling, the upper one cool white, the lower one yellow
One ceiling, two colors. Lamps replaced at different times stop matching.Photo: Marija Zaric / Unsplash
Aged lensesA row of fluorescent fixtures with prismatic lenses gone yellow along a dark corridor ceiling
Yellowed prismatic lenses. A new tube still shines through them.Photo: Pálok Rádhásjám / Unsplash

An LED tube replaces the lamp and nothing else. The lens, reflector, housing and the grid of bright rectangles stay exactly as they were.

03New fixtures change the room

Troffer gridOpen office under a ceiling grid of lay-in troffers, rows of blue cubicle panels
Lay-in troffers. A grid of bright tiles over every desk.Photo: kate.sade / Unsplash
Linear runsOpen office with long suspended linear fixtures under an open black ceiling, wood floor and desks
Suspended linear. Continuous lines under an open ceiling.Photo: Petr / Unsplash
TroffersLong corridor with block walls and a line of lay-in troffers down the center of a tile ceiling
Corridor, lay-in troffers.Photo: Quilia / Unsplash
Linear slotsCorridor with three continuous linear fixtures running its length under a concrete ceiling
Corridor, continuous linear. The lines lead down the hall.Photo: PHC Software / Unsplash

Real buildings, not the same rooms before and after.

On the ceiling now Relight with From the spec sheet
1- or 2-lamp 4 ft strip Linear™ Strip 4 ft · 40 W · 5,200 lm · 3500/4000/5000K · 0–10V
Suspended T5 or T8 runs LinearLux™ 4 ft · 40 W · 4,600 lm · 3000/4000/5000K · 0–10V · linkable
4-lamp T8 high bay LinearBeam™ 2 ft · 110 W · 13,200 lm · 5000K · 1–10V
6-lamp T5HO high bay LinearBeam™ TwistXL 4 ft · 225 W · 30,375 lm · 5000K · tilting panels · 0–10V

Match lumens, not watts. Read input watts off the existing ballast label.

A new fixture also brings 0–10V dimming and a selectable color temperature, with a new lens, housing and driver instead of the old ones.

04Tubes only? Type A, B or C

Three ways an LED tube goes into a fluorescent fixture: Type A keeps the ballast, Type B removes it and feeds the sockets at line voltage, Type C replaces it with a remote LED driverThree ways an LED tube goes into a fluorescent fixture: Type A keeps the ballast, Type B removes it and feeds the sockets at line voltage, Type C replaces it with a remote LED driver

On Type B, the sockets decide the wiring: a single-ended tube needs non-shunted sockets. Wire to the tube’s diagram, not the old ballast’s.

T8 LED Tube: Type A or B, 4 ft, 18 W, 2,160 lm, 5000K, 120–277 V, retrofit labels in the box. Not dimmable, so a fixture on a dimming ballast needs a new fixture.

05Keep the egress light

A fluorescent emergency ballast can’t run an LED tube. After a Type B conversion, that egress light goes dark. Rebuild it with a battery fixture such as Linear™ HighBay EM (90 minutes built in), or add Emergency™ ExPower to a 0–10V LED fixture (15 or 30 W for 90 minutes).

Battery inside or added: emergency lighting for linear runs →

06Before it’s priced

Per fixture type, write down

  • Lamp code: F32T8, F54T5HO, U-bend, PL 4-pin
  • Ballast label: start type, input watts, dimming
  • Sockets: shunted or non-shunted
  • Emergency ballast: test switch or charge light
  • Lens and housing: keep or replace
  • Lamps coming down: recycled as universal waste

Quick answers

Can you still buy fluorescent bulbs and T8 tubes in Illinois after Jan 1, 2027?

Not as new products. 415 ILCS 5/21.8 bars selling, offering for sale or distributing new linear fluorescent lamps, T5 through T12, and pin-base CFLs in Illinois from that date.

Do installed fluorescent fixtures have to come out?

No. The law covers the sale of lamps. Fixtures and lamps already installed can stay until they fail.

Are ballasts or fixtures banned?

No. Ballasts and fixtures are not in Section 21.8.

Is there a sell-off period for stock already in the state?

The Illinois text has none. Washington’s law, which starts Jan 1, 2029, allows six months; Illinois does not.

Are fluorescent lights being phased out in other states?

Yes, state by state. Vermont ended sales of 4 ft linear fluorescent lamps in 2024; Washington ends CFL and linear fluorescent sales on Jan 1, 2029. Each state writes its own lamp list and dates, so check the state the job is in.

What about U-bend and circular tubes?

Covered. The definition takes in straight, U-bend and circular lamps from 0.5 to 8 ft.

Which lamps are exempt?

Lamps made and marketed only for photocopying and projection, germicidal and high-UV work, medical and veterinary use, pharmaceutical production, spectroscopy, academic research, and CFLs for older vehicles. A lamp with no LED alternative is exempt until Jan 1, 2028; a standard 4 ft T8 has LED alternatives.

Should you add controls during a lighting retrofit? →

Lights in this article

Justin L., B2B Sales Manager at LeonLite Commercial

Justin L.

B2B Sales Manager

Contact a sales manager

Send the fixture count by type.

I’ll match each one to a new fixture or an LED tube and quote the relight before the shelf runs out.

Request a quoteSpec sheets & manuals