- 2700–6500K
- 3 or 5 CCT steps
- 3 wattage steps
- LumeX™ · Arc™ · LinearLux™
A fixed fixture makes you choose the color temperature on the purchase order. A selectable one lets you choose it on site. On the PO, that means fewer part numbers, fewer wrong-CCT returns, and one line item that survives a late design change.
01What changes on the PO


It also shrinks attic stock. One spare covers every room, whatever color the room was set to.
02Downlights: five steps on one switch
Every LumeX™ downlight switches between 2700K, 3000K, 3500K, 4000K and 5000K. Arc™ goes from 2700K to 6500K. Same fixture, same part number. The room decides.

LumeX™ Pivotz1790 · 3″ · 35° · 580 lm · aims · 2700–5000K
LumeX™ Spotz1792 · 3″ · 30° · 450 lm · 2700–5000K
LumeX™ Ovalz1903 · 3″ · 35° · 450 lm · slot aperture
Arc™z1813 · 3″ · 36° · 780 lm · 2700–6500K
03Linear: three steps, and the exceptions
LinearLux™ switches 3000K, 4000K and 5000K. Two things to catch before the PO goes out:
| Fixture | Color temperatures | Watch for |
|---|---|---|
| LinearLux™, HO, Spread, Dual, Wash, OpticalLens, Grille, Honeycomb | 3000 / 4000 / 5000K | — |
| LinearLux™ Cluster z0453 | 4000K only | Not selectable |
| Linear™ Strip z1598, SlimLine™ Comfort z1600 | 3500 / 4000 / 5000K | No 3000K |
| Vapor Tight EM z2102, z2103 | 4000 / 5000 / 6000K | Runs cooler |
“3CCT” on a quote tells you how many steps, not which ones. Ask for the range.
04Wattage switches: one fixture, three light levels
Several emergency linears also switch power. Same housing: less light under a low ceiling, more under a high one. One part number either way.


| Fixture | Watts | Lumens |
|---|---|---|
| LinearLux™ HO EM z2100 | 40 / 50 / 60 W | 4,600 / 5,750 / 6,900 |
| Emergency™ Pendant z1829 | 25 / 30 / 40 W | 3,250 / 3,900 / 5,200 |
| Vapor Tight EM z2102 | 50 / 60 / 70 W | 6,500 / 7,800 / 9,100 |
| Vapor Tight EM 8 ft z2103 | 80 / 100 / 120 W | up to 15,000 |
05Five rules for a clean selectable order
- Write the setting on the fixture schedule. “z1790 @ 3000K”, not just “z1790”.
- Set it before the fixture goes into the ceiling. Changing it later means pulling the fixture.
- One room, one setting. Mixed color in one space is the complaint you hear first.
- Keep one spare pool, not one per color.
- Read the range, not the count. 3000–5000K and 3500–5000K are both “3CCT”.
Lights in this article
LumeX™ Pivot z17903″ · 35° · 580 lm · aims · 2700–5000KView →
LumeX™ Spot z17923″ · 30° · 450 lm · 2700–5000KView →
LumeX™ Oval z19033″ · 35° · 450 lm · slot apertureView →
Arc™ z18133″ · 36° · 780 lm · 2700–6500KView →
LinearLux™ z05464 ft · 40 W · 4,600 lm · 3000/4000/5000K · 0–10VView →
LinearLux™ HO EM z21004 ft · 40/50/60 W · up to 6,900 lm · 90-min batteryRequest a quote →
Emergency™ Pendant z18294 ft · 25/30/40 W · up to 5,200 lm · UL 924 driverView →
Vapor Tight EM z21024 ft · 50/60/70 W · up to 9,100 lm · 90-min batteryRequest a quote →

Justin L.
B2B Sales Manager
Contact a sales manager
Send the fixture schedule as it stands.
I’ll mark which lines collapse into one part number, then quote it.
- Email Justinjustin.l@leonlite.comPlans, schedules, spec questions
- Call or text(949) 279-7251Mon–Fri 8:30 AM–4 PM PT
- Main line800-990-7688LeonLite Commercial · Eastvale, CA














Share:
Fundamentals of Energy-Efficient Lighting and Controls